Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Braz. oral res. (Online) ; 29(1): 1-7, 2015. tab, ilus
Artigo em Inglês | LILACS | ID: lil-777175

RESUMO

Three-dimensional imaging modalities have been reported to be more accurate than panoramic radiographs (PR) for the assessment of bone components of the temporomandibular joint (TMJ). No exact prior information is available that demonstrates which specific limitations occur in terms of TMJ diagnosis when using PR for this purpose. This study aimed to assess the clinical validity of digital panoramic radiography (DPR) when diagnosing morphological disorders of the TMJ using cone-beam computed tomography (CBCT) images as the gold standard. A sample composed of TMJ images (N = 848), including 212 DPR and 212 CBCT images obtained from the same patient, was used to assess any morphological changes in the TMJ. Four appraisers diagnosed all of the DPR images, whereas the CBCT images were used to establish the gold standard. The reliability of each appraiser’s response pattern was analyzed using the Kappa test (κ), and diagnostic tests were performed to assess each appraiser’s performance using a significance level setting of 5% (α = 0.05). Reliability of each appraiser’s response pattern compared to the gold standard ranged from a slight-to-moderate agreement (0.18 ≤ κ ≤ 0.45); and among the different appraisers, the response pattern showed a fair agreement (0.22 ≤ κ ≤ 0.39). Diagnostic tests showed a wide range among the different possible morphological changes diagnosed. DPR does not have validity when diagnosing morphological changes in the TMJ; it underestimates the radiological findings with higher prevalence, and thus, it cannot be used effectively as a diagnostic tool for bone components within this region.


Assuntos
Adolescente , Adulto , Idoso , Humanos , Pessoa de Meia-Idade , Adulto Jovem , Tomografia Computadorizada de Feixe Cônico/normas , Radiografia Dentária Digital/normas , Radiografia Panorâmica/normas , Transtornos da Articulação Temporomandibular , Brasil/epidemiologia , Tomografia Computadorizada de Feixe Cônico/métodos , Imageamento Tridimensional/métodos , Imageamento Tridimensional/normas , Registros Médicos , Côndilo Mandibular , Prevalência , Reprodutibilidade dos Testes , Radiografia Dentária Digital/métodos , Radiografia Panorâmica/métodos , Sensibilidade e Especificidade , Transtornos da Articulação Temporomandibular/epidemiologia
2.
Braz Dent J ; 22(2): 129-33, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21537586

RESUMO

The aim of this study was to evaluate the accuracy on the diagnosis of secondary caries-like lesions simulated on esthetic restorations of different materials, changing the incidence vertical angle (IVA) of the x-ray beam. Twenty human teeth received MOD inlay preparations. In the experimental group (n=10), a round cavity was made in the floor of the proximal box to simulate the caries-like lesion. All teeth were restored with 3 composite resins (Charisma, Filtek-Z250 and TPH-Spectrum) at 3 moments. Two radiographic images were acquired with 0º and 10º IVA. Ten observers evaluated the images using a 5-point confidence scale. Intra- and interobserver reliability was analyzed with the Interclass Correlation Coefficient and the diagnostic accuracy was evaluated using the area under the ROC curve (A(z)), Friedman test and Wilcoxon test (α=0.05). Higher accuracy values were obtained with 10º IVA (A(z)=0.66, Filtek-Z250>A(z)=0.56, TPH-Spectrum) compared to 0º (A(z)=0.55, Charisma>A(z)=0.37, TPH-Spectrum), though without statistically significant difference (p>0.05). The detection of secondary caries-like lesions simulated on esthetic restorations of different materials suffered no negative influence by changing the IVA of the x-ray beam.


Assuntos
Cárie Dentária/diagnóstico por imagem , Restauração Dentária Permanente/efeitos adversos , Radiografia Interproximal/métodos , Distribuição de Qui-Quadrado , Resinas Compostas , Cárie Dentária/etiologia , Restauração Dentária Permanente/métodos , Estética Dentária , Humanos , Variações Dependentes do Observador , Curva ROC , Estatísticas não Paramétricas
3.
Braz. dent. j ; 22(2): 129-133, 2011. tab
Artigo em Inglês | LILACS | ID: lil-583801

RESUMO

The aim of this study was to evaluate the accuracy on the diagnosis of secondary caries-like lesions simulated on esthetic restorations of different materials, changing the incidence vertical angle (IVA) of the x-ray beam. Twenty human teeth received MOD inlay preparations. In the experimental group (n=10), a round cavity was made in the floor of the proximal box to simulate the caries-like lesion. All teeth were restored with 3 composite resins (Charisma, Filtek-Z250 and TPH-Spectrum) at 3 moments. Two radiographic images were acquired with 0º and 10º IVA. Ten observers evaluated the images using a 5-point confidence scale. Intra- and interobserver reliability was analyzed with the Interclass Correlation Coefficient and the diagnostic accuracy was evaluated using the area under the ROC curve (Az), Friedman test and Wilcoxon test (α=0.05). Higher accuracy values were obtained with 10º IVA (Az=0.66, Filtek-Z250>Az=0.56, TPH-Spectrum) compared to 0º (Az=0.55, Charisma>Az=0.37, TPH-Spectrum), though without statistically significant difference (p>0.05). The detection of secondary caries-like lesions simulated on esthetic restorations of different materials suffered no negative influence by changing the IVA of the x-ray beam.


O objetivo deste estudo foi avaliar a precisão no diagnóstico de lesões iguais-à-cárie secundárias simuladas em restaurações estéticas de materiais diferentes, mudando o ângulo vertical de incidência (AVI) do feixe de raios-x. Vinte dentes humanos foram submetidos a preparo cavitário inlay MOD. No grupo experimental (n=10), no soalho da caixa de proximal, foi confeccionada uma cavidade esférica para simular lesões iguais-a-cárie. Todos os dentes foram restaurados com 3 resinas compostas (Charisma, Filtek-Z250, TPH-Spectrum), em três tempos diferentes. Duas imagens radiográficas foram adquiridas com 0 e 10 graus de AVI o feixe de raios-x. Dez observadores avaliaram as imagens usando uma escala de confiança de 5-pontos. A reprodutibilidade intra- e inter- observador foi analisada com o coeficiente de correlação interclasse e a precisão do diagnóstico foi avaliada usando a área sob a curva ROC (Az), o teste de Friedman e de Wilcoxon (α=0,05). Os mais altos valores de precisão (p>0,05) foram observados com o AVI em 10º (Filtek-Z250 Az=0,66>TPH-Spectrum Az=0,56) comparado com 0º (Charisma Az=0,55>TPH-Spectrum Az=0,37), porém, sem diferenças estatisticamente significantes (p>0,05). A detecção de lesões iguais-à-cárie secundárias simulada em restaurações estéticas de diferentes materiais não foi influenciada pela mudança de AVI do feixe de raios-x.


Assuntos
Humanos , Cárie Dentária , Restauração Dentária Permanente/efeitos adversos , Radiografia Interproximal/métodos , Distribuição de Qui-Quadrado , Resinas Compostas , Cárie Dentária/etiologia , Restauração Dentária Permanente/métodos , Estética Dentária , Variações Dependentes do Observador , Curva ROC , Estatísticas não Paramétricas
4.
Rev. ABRO ; 12(01): 44-48, 2011. ilus
Artigo em Português | BBO - Odontologia | ID: biblio-855336

RESUMO

O objetivo deste trabalho foi avaliar a eficácia da adição de cilindros localizadores com colimadores retangulares, de comprimento curto e longo, na dose de exposição em radiografias periapicais...


Assuntos
Proteção Radiológica/normas , Radiografia Dentária/normas , Controle de Qualidade
5.
Braz Dent J ; 21(5): 458-62, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-21180804

RESUMO

The aim of this study was to determine size, shape and position of the image layer by evaluation of the radiographic image formation in different anatomic positions. A customized phantom was made of a rectangular acrylic plate measuring 14 cm² and 0.3 cm thick, with holes spaced 0.5 cm away and arranged in rows and columns. Each column was separately filled with 0.315 cm diameter metal spheres to acquire panoramic radiographs using the Orthopantomograph OP 100 unit. The customized phantom was placed on the mental support of the device, with its top surface kept parallel to the horizontal plane, and was radiographed at three different heights from the horizontal plane, i.e., the orbital, occlusal and mandibular symphysis levels. The images of the spheres were measured using a digital caliper to locate the image layer. The recorded data were analyzed statistically by the Student'-t test, ANOVA and Tukey' test (?=0.05). When the image size of spheres in horizontal and vertical axes were compared, statistically significant differences (p<0.05) were observed in all areas, portions of the image layer and heights of horizontal plane evaluated. In the middle portion of the image layer, differences in the image size of spheres were observed only along the horizontal axis (p<0.05), whereas no differences were observed along the vertical axis (p>0.05). The methodology used in this determined the precise size, shape and position of the image layer and differences in magnification were observed in both the horizontal and vertical axes.


Assuntos
Intensificação de Imagem Radiográfica/métodos , Radiografia Panorâmica/métodos , Desenho de Equipamento , Marcadores Fiduciais , Humanos , Mandíbula/diagnóstico por imagem , Órbita/diagnóstico por imagem , Imagens de Fantasmas , Ampliação Radiográfica , Dente/diagnóstico por imagem
6.
Braz. dent. j ; 21(5): 458-462, 2010. ilus, tab
Artigo em Inglês | LILACS | ID: lil-568993

RESUMO

The aim of this study was to determine size, shape and position of the image layer by evaluation of the radiographic image formation in different anatomic positions. A customized phantom was made of a rectangular acrylic plate measuring 14 cm² and 0.3 cm thick, with holes spaced 0.5 cm away and arranged in rows and columns. Each column was separately filled with 0.315 cm diameter metal spheres to acquire panoramic radiographs using the Orthopantomograph OP 100 unit. The customized phantom was placed on the mental support of the device, with its top surface kept parallel to the horizontal plane, and was radiographed at three different heights from the horizontal plane, i.e., the orbital, occlusal and mandibular symphysis levels. The images of the spheres were measured using a digital caliper to locate the image layer. The recorded data were analyzed statistically by the Student'-t test, ANOVA and Tukey' test (?=0.05). When the image size of spheres in horizontal and vertical axes were compared, statistically significant differences (p<0.05) were observed in all areas, portions of the image layer and heights of horizontal plane evaluated. In the middle portion of the image layer, differences in the image size of spheres were observed only along the horizontal axis (p<0.05), whereas no differences were observed along the vertical axis (p>0.05). The methodology used in this determined the precise size, shape and position of the image layer and differences in magnification were observed in both the horizontal and vertical axes.


O objetivo na presente pesquisa foi determinar o tamanho, forma e posição da camada de imagem por meio da avaliação da formação da imagem radiográfica em diferentes posições anatômicas. Foi construído um phantom constituído por uma placa acrílica de 14 cm² e 0,3 cm de espessura, com sua superfície contendo perfurações a cada 0,5 cm dispostas em linhas e colunas. O phantom foi posicionado no local do apoio de mento do aparelho panorâmico, com sua superfície paralela ao plano horizontal. Esferas metálicas de 0,315 cm foram inseridas nas perfurações, e executadas radiografias panorâmicas. Cada coluna de cada quadrante foi individualmente preenchida pelas esferas para a execução das radiografias, em três planos horizontais diferentes: alturas orbital, oclusal e mentual. As imagens das esferas foram medidas com o uso de um paquímetro digital e a camada de imagem localizada. Os dados foram analisados estatisticamente utilizando-se o teste T Student, ANOVA e teste de Tukey (?=0,05). Quando o tamanho das esferas nos eixos horizontal e vertical foi comparado, diferenças estatisticamente significativas (p<0,05) foram observadas em todas as áreas da camada de imagem, porções e alturas do plano horizontal avaliado. Na porção central da camada de imagem diferenças no tamanho das esferas foram observadas somente no eixo horizontal (p<0,05), enquanto que no eixo vertical nenhuma diferença foi observada (p>0,05). A metodologia utilizada determinou com precisão o tamanho, forma e posição da camada de imagem, e diferenças de ampliação foram observadas tanto no eixo horizontal quanto vertical.


Assuntos
Humanos , Intensificação de Imagem Radiográfica/métodos , Radiografia Panorâmica/métodos , Desenho de Equipamento , Marcadores Fiduciais , Mandíbula , Órbita , Imagens de Fantasmas , Ampliação Radiográfica , Dente
7.
Braz Oral Res ; 22(1): 78-83, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18425250

RESUMO

This study aimed at investigating the effect of the partial erasing of DenOptix system storage phosphor plates on the image quality of digital radiographs. Standardized digital radiographs were acquired of a phantom mandible, using size 2 intraoral DenOptix storage phosphor plates (n = 10). Subsequently, the active areas of the plates were placed in a viewing box with a constant light intensity of 1,700 lux for 130 seconds to achieve complete erasing (control plate), as well as for 0, 5, 10, 15, 20, 25, 34, 66, and 98 seconds, to compose the experimental group of partially erased plates. The same exposure settings were repeated using the control and experimental plates, which were scanned at a resolution of 300 dpi. Five radiologists independently examined the pairs of digital radiographs obtained with the control and partially erased plates, in random order, and indicated the best image for oral diagnosis. Cochran-Mantel-Haenszels chi-square test, at a significance level of 5%, was used to compare the percentages of superior quality images in each combination of control and partially erased plates, subjectively assessed. No significant differences were found between radiographic images acquired with control and partially erased plates, except for the combination of 0 second (30%) versus 130 seconds (70%), p = 0.0047. It can be concluded that, under adequate light intensity conditions, erasing intraoral DenOptix storage phosphor plates may require time intervals of as little as 5 seconds.


Assuntos
Intensificação de Imagem Radiográfica/normas , Ampliação Radiográfica/normas , Radiografia Dentária Digital/normas , Distribuição de Qui-Quadrado , Processamento de Imagem Assistida por Computador , Luz , Medições Luminescentes , Imagens de Fantasmas , Intensificação de Imagem Radiográfica/métodos , Ampliação Radiográfica/métodos , Radiografia Dentária Digital/métodos , Software , Fatores de Tempo , Ecrans Intensificadores para Raios X
8.
Braz. oral res ; 22(1): 78-83, Jan.-Mar. 2008. ilus, tab
Artigo em Inglês | LILACS | ID: lil-480588

RESUMO

This study aimed at investigating the effect of the partial erasing of DenOptix® system storage phosphor plates on the image quality of digital radiographs. Standardized digital radiographs were acquired of a phantom mandible, using size 2 intraoral DenOptix® storage phosphor plates (n = 10). Subsequently, the active areas of the plates were placed in a viewing box with a constant light intensity of 1,700 lux for 130 seconds to achieve complete erasing (control plate), as well as for 0, 5, 10, 15, 20, 25, 34, 66, and 98 seconds, to compose the experimental group of partially erased plates. The same exposure settings were repeated using the control and experimental plates, which were scanned at a resolution of 300 dpi. Five radiologists independently examined the pairs of digital radiographs obtained with the control and partially erased plates, in random order, and indicated the best image for oral diagnosis. Cochran-Mantel-Haenszel’s chi-square test, at a significance level of 5 percent, was used to compare the percentages of superior quality images in each combination of control and partially erased plates, subjectively assessed. No significant differences were found between radiographic images acquired with control and partially erased plates, except for the combination of 0 second (30 percent) versus 130 seconds (70 percent), p = 0.0047. It can be concluded that, under adequate light intensity conditions, erasing intraoral DenOptix® storage phosphor plates may require time intervals of as little as 5 seconds.


Assuntos
Intensificação de Imagem Radiográfica/normas , Ampliação Radiográfica/normas , Radiografia Dentária Digital/normas , Distribuição de Qui-Quadrado , Processamento de Imagem Assistida por Computador , Luz , Medições Luminescentes , Imagens de Fantasmas , Intensificação de Imagem Radiográfica/métodos , Ampliação Radiográfica/métodos , Radiografia Dentária Digital/métodos , Software , Fatores de Tempo , Ecrans Intensificadores para Raios X
9.
Braz. dent. j ; 18(3): 208-214, 2007. ilus, tab
Artigo em Inglês | LILACS | ID: lil-471442

RESUMO

The aim of this study was to assess the effect of low-dose electron irradiation on morphological features of the wound healing process in rat skin. Surgical wounds were inflicted with a 2.3 x 1.4 cm template on 84 male rats that were assigned to 4 groups: IG1, immediately irradiated; IG2, irradiated 3 days after inflicting the wound; CG1 and CG2, control groups. Rats in IG1 and IG2 groups had their wounds exposed to 1 Gy of 6 MeV electron beam radiation, immediately after surgery and on the third postoperative day, respectively. Qualitative and histophotometric evaluations of tissue repair structures were carried out. Data were analyzed by ANOVA and Tukey's test (alpha = 0.05) and regression analysis. The repair process was delayed since the first sacrifice time in both irradiated groups, but in IG1, wound healing was closer to that of CG1; whereas in IG2, the delay was more pronounced. Based on the histological findings, it is possible to conclude that a low-dose of electron radiation delayed tissue repair in rat skin. The delay was longer in the skin irradiated 3 days after the beginning of tissue repair. However, the low-energy electron irradiation did not prevent wound healing.


O objetivo deste estudo foi avaliar o efeito da irradiação por baixa dose de elétrons sobre características morfológicas da reparação tecidual na pele de rato. Foram realizadas feridas cirúrgicas com um gabarito de 2,3 x 1,4 cm em 84 ratos machos, divididos em 4 grupos: IG1, irradiado imediatamente; IG2, irradiado 3 dias após a produção da ferida; CG1 e CG2, grupos controles. Os ratos dos grupos IG1 e IG2 tiveram suas feridas expostas a 1 Gy de radiação por elétrons com 6 MeV, imediatamente após a cirurgia e ao terceiro dia pós-operatório, respectivamente. Procedeu-se às avaliações qualitativas e histofotométrica das estruturas de reparação tecidual. Os dados foram submetidos a ANOVA e teste Tukey (a = 0,05) e análise de regressão. O processo de reparação apresentou-se atrasado desde o primeiro tempo de sacrifício em ambos os grupos irradiados, mas para IG1, a reparação tecidual foi similar a CG1. Por outro lado, para IG2, o retardo foi mais pronunciado. Com base nas avaliações histológicas, é possível concluir que uma baixa dose de radiação por elétrons retardou a reparação na pele de rato. O atraso foi maior na pele irradiada 3 dias após o início da reparação tecidual. No entanto, esta irradiação por elétrons de baixa energia não impediu a cicatrização.


Assuntos
Animais , Masculino , Ratos , Partículas beta , Glicosaminoglicanos/efeitos da radiação , Tecido de Granulação/efeitos da radiação , Pele/efeitos da radiação , Cicatrização/efeitos da radiação , Relação Dose-Resposta à Radiação , Glicosaminoglicanos/metabolismo , Tecido de Granulação/metabolismo , Doses de Radiação , Ratos Wistar , Pele/metabolismo , Pele/cirurgia , Fatores de Tempo , Cicatrização/fisiologia
10.
Rev. ABRO ; 7(2): 147-152, jul.-dez. 2006. ilus, graf
Artigo em Português | BBO - Odontologia | ID: biblio-855422

RESUMO

O objetivo com este estudo foi avaliar a adequação de equipamentos de raio X, usados para realização de radiografias intrabucais, quanto às normas de proteção radiológica por meio da verificação do sistema de colimação, do uso de sistema de alinhamento e posicionamento do filme, da distância foco-extremidade de saída do localizador, do kVp nominal e do formato e comprimento do localizador. Com relação aos tamanhos de campo preconizados na portaria 453 apenas 38 por cento dos equipamentos estavam em conformidade com os valores exigidos e 32 por cento apresentaram-se de acordo com os valores aceitos. Porém, destes 32 por cento, uma porcentagem de 16 por cento não utilizava sistema de alinhamento e posicionamento de filme, portanto, estavam em desarcordo com os preceitos da portaria...


Assuntos
Doses de Radiação , Proteção Radiológica/instrumentação , Equipamentos Odontológicos/classificação , Radiografia Dentária/instrumentação
11.
Rev. ABRO ; 7(2): 153-158, jul.-dez. 2006. ilus
Artigo em Português | BBO - Odontologia | ID: biblio-855423

RESUMO

A International Commission on Radiogical Protection (ICRP) e o Ministério da Saúde, no Brasil, por meio da Portaria 453, definiram as recomendações básicas de proteção radiológica, indicando o uso de diversos tipos de manequins chamados phantoms ou fantomas visando a diminuição da dose de radiação proveniente de exposições deliberadas a seres humanos. A realização deste trabalho teve como objetivo desenvolver um fantoma antropomórfico de cabeça para uso didático-pedagógico em cursos de odontologia. Como material para confecção do fantoma, foi utilizado um crãnio humano macerado, com integridade anatômica, e simulador do tecido mole, com adequada capacidade para atenuar, absorver e espalhar a radiação. Foram selecionados dois tipos de materiais como simulador de tecido mole, um para fornecer as características de absorção, atenuação e espalhamento de radiação e outro para reproduzir a anatomia da face sem a função de interagir com a radiação...


Assuntos
Proteção Radiológica/métodos , Proteção Radiológica/normas , Radiação Ionizante
12.
Rev. Assoc. Paul. Cir. Dent ; 60(5): 357-360, set.-out. 2006. tab, graf
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-543814

RESUMO

O objetivo neste estudo foi comparar a precisão das imagens radiográficas realizadas com posicionadores de três diferentes marcas: Rinn XCP utilizando localizador curto e longo, Hanshin e lndusbello com localizador curto. As médias das medidas radiográficas foram calculadas e comparadas com o tamanho original dos dentes. Os resultados foram submetidos à análise de variância e ao teste de Tukey com a=0,05. Todos os posicionadores analisados ampliaram o tamanho da imagem sendo que o da Rinn XCP com localizador longo promoveu a menor ampliação. Não houve diferença estatisticamente significativa entre Rinn XCP com localizador longo e Hanshin. Os posicionadores da técnica da bissetriz e do paralelismo, quando utilizados com as distâncias recomendadas, possibilitaram a obtenção de mensurações dentárias próximas ao tamanho real.


The objective with this work was to compare the radiographic images precision of the dental elements accomplished with film holders of three different brand: RINN XCP used short and long beam-indicating devices, HANSHIN and INDUSBELLO used short beam-indicating devices. The mean measurements of radiographic image were calculated and compared with the teeth length size. All the film holders analyzed promoted the magnified radiographic and the RINN XCP's film holders with long beam indicating device promoted the minor magnified. No significant differences were found among RINN XCP's film holders with long beam-indicating device and HANSHIN. The film holders for the parallel and bisecting-the-angle technique when used with the recommended distances make possible to obtain radiographic image measurements close tooth length size.


Assuntos
Humanos , Diagnóstico por Imagem , Ampliação Radiográfica , Radiografia
13.
Rev. ABRO ; 6(1): 25-28, jan.-jun.2005. ilus, tab
Artigo em Português | BBO - Odontologia | ID: biblio-855404

RESUMO

Para saber se o valor do coeficiente de variação (CV) é considerado baixo, médio, alto ou muito alto, é importante avaliar a quantidade do experimento por meio da magnitude do erro experimental que este indica. Este estudo teve como objetivo analisar os artigos publicados na área de radiologia Odontológica, para calcular o coeficiente de variação médio e então classificá-lo como baixo, médio, alto e muito alto. Neste estudo, 394 artigos publicados no periódico Dentomaxillofacial Radiology foram avaliados e os dados como média e desvio padrão foram coletados, sendo o coeficiente de variação calculado. também foram coletados outros dados, como a utilização ou naõ de análises estatísticas, resultados apresentados em gráficos, testes estatísticos e medidas de dispersão utilizadas. Para os artigos avaliados que apresentaram desvio padrão, o coeficiente de variação para cada variável quantitativa foi calculado, obtendo-se o CV médio de todos os artigos de 15, 36 por cento com desvio padrão de 13,20 por cento. A importância de se realizar esta classificação é melhorar a precisão dos experimentos e manter a alta quantidade das pesquisas


Assuntos
Interpretação Estatística de Dados , Radiografia Dentária/estatística & dados numéricos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...